ÁÏÑÊ ÑÏÇ unit
Signal converting and aircraft fire alarm system control unit (ÁÏÑÊ ÑÏÇ) is designed for performing the following functions on earth and in flight: |
|
- to receive signals from fire sensors in the form of e.m.f. and to convert them; - to analyze the condition of ignition cylinders and pressure sensors of fire extinguishers; - to give fire alarm signals to fire alarm system (FAS) panel, to failure recorder and failure alarm system; - to perform automatic fire sensors channels readiness control in flight and testing control of fire alarm system readiness control on earth before flight; - to give signals on failures to built-in tabular display; - to perform automatic activation of the first set of fire extinguishers after signal and to provide manual activation of extinguishers from FAS panel; - to perform automatic activation of extinguishers in the engine nacelles when emergency landing on fuselage. |
|
|
||||||||||||||||||||||||||||||
|
On
the questions of instruments purchasing , warranty and afterwarranty
Service please turn to "ZAT Ukranalyt" (Allukrainian institute
for analytical instrumentation) on Address : |