Three-channel methane signalling device 123ÒÕ 05

123ÒÕ 05 Automatic three-channel signalling device is designed for continuous control of methane leak in motor compartments, gas cylinder cells and in gas and gas-diesel bus compartments.

Signalling device monitors methane concentration and gives sound and light signal in case of exceeding methane signal set concentrations.

Specifications

Principle of measurement

thermochemical sensor

Range of conversion

0 – v.p.2,5 % (0-50 % MFDCL)

Permissible main absolute conversion error limits 

± v.p.0,25 % (5% MFDCL)

Limits of permissible main absolute error of threshold devices operation

± v.p.0,05 %

Values for signal concentrations when sound and light (red light) signalling is given:

«Threshold 1»

 

 

v.p.1 % (20 % MFDCL)

«Threshold 2»

v.p.2 % (40 % MFDCL)

Signalling threshold devices operating time

15 sec

Supply

(24 (+6/—2,4) V D/C

Power intake

10 VA

Time of operation without controlling and tuning threshold devices

1 year or 25000 km of the bus run

Monitored air mix supply

convectional

Light signalling:

 

- switching in «24 V»

green light

- break or burning-out ×Ý «Failure ×Ý»

yellow light

Weight, not more than

1,0 kg

Dimensions, not more than:

 

-  signalling unit

110´160´55 mm

-  measuring converters

100´65´35 mm

Range of operating temperatures:

 

- for signalling unit

from – 45  to + 40 0Ñ

- for measuring converters

from – 45 to + 70 0Ñ

A list of instruments allocated on this site

On the questions of instruments purchasing , warranty and afterwarranty Service please turn to "ZAT Ukranalyt" (Allukrainian institute for analytical instrumentation) on Address : 
6, Tverska str, 03150, Kyiv, Ukraine
tel. +38044-529 - 62 - 13, fax +38044-502 - 13 - 68,
Our e-mail for requests:E-mail: analyt@ukranalyt.com.ua
or contact to the official sales representative – KSM - 05 Ltd.
 
Tel.:
(38 044) - (502 - 13 - 53), Fax: (38 044) - (502 - 13 - 59).
E-mail: ksm05@ukr.net

Home page